Inspection #: 505061
Inspection Type: Electrical Service
Inspector: M.Green
Result: Partial
Comment: SPACE 258 AM Requested by: OWNER 231-5598 Moble home rough electrical set-up approved. Tag #33878. Call for final after energized but before occupying.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
2/7/2018CorrectedCorrect service item below* All exterior receptacles including under trailer.Need GFCI protection. Receptacles under trailer will need GFCI device to be readily accessible.
2/7/2018CorrectedCorrect service item below* Type URD feeder conductors under trailer.Need coreflow or conduit protection.
2/7/2018CorrectedCorrect service item below* Underground direct burrial feeder conductors.Need to be 24 inches deep minimum. Conductors in PVC or liquid tight need to be 18 inches deep min. Ridgid or IMC can be 6 inches deep min.