Inspection #: 485258
Inspection Type: Plumbing Rough
Inspector: Y.Dovba
Result: Partial
Comment: Dwv and Water piping rough-in and tests Approved. Per Plans P1.1B & P.1. Highlighted, Initialed and Dated on Ralph's field set. Inspection covers all of Bar area and overhead piping within the kitchen wall, With all expansion loops in place. Both gang restrooms and single private restrooms and Lavs including overhead piping supplying restrroms. NOTE 1) Hammer arresters will be installed after testing. NOTE 2) Temp valves installed on lav piping.