| Date | Status | Code | Description | Ref | Location | Comments |
| 6/30/2017 | Transfer | 01 | See inspection comments | | Under mobile home. | Support, fasten MC cable off of ground to trailer frame. |
| 6/30/2017 | Transfer | 01 | See inspection comments | | Exterior receptacles. | Verify GFCI protection. If replacing receptacle(s) will need to be weather resistant and tamper resistant type with "extra duty" weatherproof cover. |
| 6/30/2017 | Transfer | 01 | See inspection comments | | Headbolt heater receptacle. | Receptacle needed by parking area for plugging-in car engine block heaters. Needs dedicated circuit. Needs "extra-duty" weatherproof cover. Needs GFCI protection. Receptacle will need to be tamper resistant and weather resistant type. |
| 6/30/2017 | Transfer | 01 | See inspection comments | | Jacuzzi tub. | Needs GFCI breakers for motor and heater. Needs 16 inch by 16 inch access panel. Receptacles need to face access. |
| 6/30/2017 | Transfer | 01 | See inspection comments | | Kitchen conuntertop. | Receptacles need GFCI protection. |
| 6/30/2017 | Transfer | 01 | See inspection comments | | Panel. | Needs deadfront and cover that fits that enclosure, panel schedule. |
| 6/30/2017 | Transfer | 01 | See inspection comments | | Feeder J-box under mobile home. | Needs ground wire connections. |
| 6/30/2017 | Transfer | 01 | See inspection comments | | Water line and gas line under trailer. | Needs #6 copper grounding electrode conductor from panel. Do not run through metal conduit. Cannot be spliced. |
| 6/30/2017 | Transfer | 01 | See inspection comments | | 3-wire feeder from service. | Mobile home is more than 30 feet from service. Needs post mounted disconnect at the trailer space. Also requires the following: *Treated wood for post. *Disconnect needs to be labelled "suitable for use as service equipment". *(2) ground rods needed at post mounted disconnect. *Connect ground rods to disconnect with #6 copper wire. *Bond neutral to ground at disconnect. *Feeder from post mounted disconnect into mobile home needs to include a #6 copper ground wire. *Feeder underground from post mounted disconnect to trailer will need to be burried 24 inches deep and inspected before cover. *Coreflow will need to cover feeders completely where above ground under mobile home. |