Inspection #: 433131
Inspection Type: Ceiling Rough Electrical
Inspector: H8
Result: Partial
Comment: Sales floor area, above T-bar grid ceiling electrical rough approved. Sales floor lighting to be lighting track and (1) chandalier is not installed at this time due to painting of grid and tiles. Track lighting to have seismic wires to structure at 4ft intervals max and use standard Caddy grid fasteners. Sufficient ceiling tiles to be left out to be able to inspect seismic support and connections to lighting track at final.