| 10/21/2016 | Transfer | Violation Below | * | | Junction boxes undersized for amount of cables spliced. Additional boxes may be req'd. (4-11/16 inch deep bracketed) | |
| 10/21/2016 | Transfer | Violation Below | * | | #12 awg wire req'd for 20 amp ckt. (yellow). | |
| 10/21/2016 | Transfer | Violation Below | * | | Properly ground metal boxes. | |
| 10/21/2016 | Transfer | Violation Below | * | | fasten cable within 12" of box. | |
| 10/21/2016 | Transfer | Violation Below | * | | Ensure ckts are reconnected to proper breaker. | |
| 10/21/2016 | Transfer | Violation Below | * | | Orientate junction boxes to be accessible after siding is installed. | |
| 10/21/2016 | Transfer | Violation Below | * | | Call for reinspect when corrections are made. | |