Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 337250
Inspection Type: Final Electrical
Inspector: M.Green
Result: Approved
Comment: Requested by: M.Green Back area remodel

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
12/26/2014 EF1Correct Below Break room refrigerator.Owner moved ref from original location. Cannot use extension cord from under sink recept. Will need GFCI protection.
12/26/2014 EF1Correct Below Break room under sink.Recept needs GFCI protection.
12/26/2014 EF1Correct Below Break room vending machine.Owner moved from location on plans. Will need readily accessable GFCI.
12/26/2014 EF1Correct Below Office walls.Some recepts in cork board walls loose, need add-a-depths. Some trim missing.
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS