Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 325166
Inspection Type: Electrical Service
Inspector: M.Green
Result: Partial
Comment: wayne Johnson 444-7387 AM

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
10/3/2014TransferES1Correct Belowsee inspectors commentFeeder j-box under trailer.There are 4 insulated conductors in feeder from meter stack. Use 1 wire as EGC, and 1 as neutral. Identify accordingly.
10/3/2014TransferES1Correct Belowsee inspectors commentFeeder j-box under trailer.Sepparate EGCs, neutrals, and GEC.
10/3/2014TransferES1Correct Belowsee inspectors commentFeeder j-box under trailer.Cannot use romex connector on individual cnductors.
10/3/2014TransferES1Correct Belowsee inspectors commentGEC under trailer.Must be continuous or spliced with a ''copper c''.
10/3/2014TransferES1Correct Belowsee inspectors commentElecrical panel.Fasten added ground bar to enclosure.
10/3/2014TransferES1Correct Belowsee inspectors commentElectrical panel.No more than (2) ground wires per terminal.
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS