Inspection #: 289442
Inspection Type: Final Structural
Inspector: H8
Result: Cancel
Comment: Correction on sink placement has been completed. Further advice on correction of non-conforming entry required. Thank you! Requested by: Fr Vasili Hillhouse 344-0190 iamvasili@gmail.com

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
3/20/2014TransferFNLSANC house #'sInstall house numbers using contrasting colors. House numbers to be clearly visible from the street. install address at street
3/20/2014TransferFNLSBNC HandrailsHandrails to be 34" - 38" above the stairs measured at the nose of the stair in a plumb line complete handrails at all stairs
3/20/2014TransferFNLSCNC GuardrailsGuardrails to be 36" above finish floor. 4" maximum opening Complete guards as required
3/20/2014TransferFNLSGFinal Structural OtherPlease correct the following: Complete firestop above ceilings at all rated wall assemblies.
3/20/2014TransferFNLSGFinal Structural OtherPlease correct the following: Bathrooms per ANSI 117.1
3/20/2014TransferFNLSGFinal Structural OtherPlease correct the following: door 105 to be 90 min