Inspection #: 261834
Inspection Type: Electrical Service
Inspector: R.Thornton
Result: Partial
Comment: Anytime! Please call first to ensure I am/will be there. Requested by: Kim 444-6007

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
8/30/2013TransferES1Correct Belowsee inspectors commentat dryerdryer cord and receptacle must be 4-prong, 4-wire grounding type plug with cable clamp at dryer
8/30/2013TransferES1Correct Belowsee inspectors commentin panelinstall #6 coppoer from neutral bus to ground bus
8/30/2013TransferES1Correct Belowsee inspectors commentat front of trailerinstall headbolt heater receptacle at front of trailer, on dedicated 20 amp circuit with in-use cover and GFCI protected
8/30/2013TransferES1Correct Belowsee inspectors commentat watermain#6 from panel to watermain must be unspliced or irreversibly spliced
8/30/2013TransferES1Correct Belowsee inspectors commentin panelback-fed main breaker must have hold down kit