| Date | Status | Code | Description | Ref | Location | Comments |
| 6/4/2013 | Transfer | FNLSA | NC house #'s | Install house numbers using contrasting colors. House numbers to be clearly visible from the street. | | install address at street |
| 6/4/2013 | Transfer | FNLSB | NC Handrails | Handrails to be 34" - 38" above the stairs measured at the nose of the stair in a plumb line | | complete handrails at all stairs |
| 6/4/2013 | Transfer | FNLSC | NC Guardrails | Guardrails to be 36" above finish floor. 4" maximum opening | | Complete guards as required |
| 6/4/2013 | Transfer | FNLSG | Final Structural Other | Please correct the following: | | Bathrooms per ANSI 117.1 |
| 6/4/2013 | Transfer | FNLSG | Final Structural Other | Please correct the following: | | door 105 to be 90 min |
| 6/4/2013 | Transfer | FNLSG | Final Structural Other | Please correct the following: | | Complete firestop above ceilings at all rated wall assemblies. |