Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 244505
Inspection Type: Final Structural
Inspector:
Result: Partial
Comment: PLEASE CALL 30 MIN B4 INSPECTION TRYING TO GET CCO JOHN MAROULIS 903-1009

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/4/2013TransferFNLSANC house #'sInstall house numbers using contrasting colors. House numbers to be clearly visible from the street. install address at street
6/4/2013TransferFNLSBNC HandrailsHandrails to be 34" - 38" above the stairs measured at the nose of the stair in a plumb line complete handrails at all stairs
6/4/2013TransferFNLSCNC GuardrailsGuardrails to be 36" above finish floor. 4" maximum opening Complete guards as required
6/4/2013TransferFNLSGFinal Structural OtherPlease correct the following: Bathrooms per ANSI 117.1
6/4/2013TransferFNLSGFinal Structural OtherPlease correct the following: door 105 to be 90 min
6/4/2013TransferFNLSGFinal Structural OtherPlease correct the following: Complete firestop above ceilings at all rated wall assemblies.
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS