Inspection #: 244184
Inspection Type: Final Structural
Inspector: D.Hickel
Result: Correction
Comment: AM PLZ - Call John @ 903-1009 1/2hr b4 coming to meet for basement only

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
6/4/2013TransferFNLSANC house #'sInstall house numbers using contrasting colors. House numbers to be clearly visible from the street. install address at street
6/4/2013TransferFNLSBNC HandrailsHandrails to be 34" - 38" above the stairs measured at the nose of the stair in a plumb line complete handrails at all stairs
6/4/2013TransferFNLSCNC GuardrailsGuardrails to be 36" above finish floor. 4" maximum opening Complete guards as required
6/4/2013TransferFNLSGFinal Structural OtherPlease correct the following: Complete firestop above ceilings at all rated wall assemblies.
6/4/2013TransferFNLSGFinal Structural OtherPlease correct the following: Bathrooms per ANSI 117.1
6/4/2013TransferFNLSGFinal Structural OtherPlease correct the following: door 105 to be 90 min