Register
My Neighborhood
Jobs
Contact Us
Home
Residents
Businesses
Government
Visitors
Departments
Public Safety
Transportation
Recreation
ePay
Maps
Services A-Z
Muni.org
>
Departments
>
Development Services
> Permit Information & Inspection Request
Click Here To Go Back To Permit Information
Permit Number:
C21-1153
Permit Type:
Commercial Building Permit - None BldgNew
Address:
W 160 48TH AVE Anchorage
Location:
160 W 48th Ave
Work Description:
EPLANS-117094 SQFT, TYPE VB, OCCUPANCY R-1-GJS
NO CCO ON THIS PERMIT UNTIL SHARED ACCESS WITH C15-1806 IS RESOLVED. JCA 6/19/23
**REVOKED MAIN PERMIT AND ISSUED CORE AND SHELL ONLY PER JUDY 6/19/23 - SEE HER COMMENTS UNDER PD CIVIL REVIEW - BWP**
Change order X22-1625 has been approved and this permit (C21-1153) has full PD Civil approval. - RDO (Per PDCivil Final Review)
Status:
Issued
Project Name:
EPLANS- CANDLEWOOD SUITES/HOLIDAY INN EXPRESS
Review Type:
Traffic Engineering
Result:
Correction
Result Date:
3/16/2021 11:30:38 AM
Comments:
Code Section
Review Comment
Status
1
21.07.040 F
Provide required snow storage area calculations.
2
21.07.040 F
Show required snow storage location on site plan or enter into snow management agreement with Municipality
3
21.07.060 E.4
Provide required on site pedestrian walkways.
4
21.07.080
No landscape drawings provided with this submittal.
5
21.07.080
Show site distance triangles for driveway access to the right of way.
6
21.07.090 B
Provide Zoning approved parking calculations for all use on proposed development site plan.
7
21.07.090 C
Provide typical dimensions for proposed parking spaces to include length, width, angle and travel aisles.
Compact spaces are not allowed per Title 21. Typical Spaces is 9ft x 20 ft. Revise space size or eliminate spaces.
8
21.07.090 G
Provide required loading berth calculations for proposed site development.
9
21.07.090 G.5
Show location of required loading berths on site plan.
10
21.07.090 H.5
Provide electrical site plan showing location of parking lot lighting with required lighting calculations and glare statement.
11
21.07.090 K
Provide minimum number of required bicycle parking spaces.
Sjow location of 4 required bicycle parking spaces on civil site plans
12
-
Height of building will require 26 foot wide drive aisle around building to support aerial fire apparatus per IFC. Contact AHJ on required widths for this site.
13
-
Show location of proposed trach dumpster for servicing by solid waste services vehicle.
14
Title 9
Provide Haul Route Information to and from proposed import and export locations. Identify Import and export locations, construction hours of operation, and point of contact.
15
MUCTD
Provide note that pavement marking shall be 4" white unless otherwise noted.
16
Incomplete
Traffic comments are incomplete pending submission of additional information. Additional Comments may be generated.
17
-
Provide Standard Signpost detail to be used with proposed site plans on site.
18
-
Provide standard wheel stop details
19
-
Provide copy of shared access agreement with parcel to the south for driveway connection to "A" street.
Advisory Information:
ADA Compliance
Privacy Statement & Disclaimer
Employee Search
eNewsletter
RSS
OFFICIAL WEB SITE OF THE MUNICIPALITY OF ANCHORAGE, ALASKA
632 West 6th Avenue, Anchorage, Alaska 99501