Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C20-1043
Permit Type: Commercial Building Permit - None BldgNew
Address: W 310 36TH AVE Anchorage
Location: ALOFT HOTEL, 146 ROOMS
Work Description: NEW CONSTRUCTION HOTEL (63,194 SQFT R-1 OCC. VA CONST.) (21,774 SQFT A-2 OCC. VA CONST).  TOTAL SQUARE FOOTAGE 84,968, 146 ROOMS - MJD
Status: Issued
Project Name: ALOFT HOTEL
Review Type: Traffic Engineering
Result: Correction
Result Date: 2/20/2020 4:24:05 PM

Comments:

 Code SectionReview CommentStatus
121.07.040 FShow required snow storage location on site plan or enter into snow management agreement with Municipality


221.07.090 GProvide required loading berth calculations for proposed site development.


321.07.090.G.7
Provide No Parking Loading Signs ( R7P-106) at proposed loading berth locations.
Provide No Parking Loading Zone signs for the 2 Type B loading berths

421.07.090 H.6Proposed parking spaces dimensions overhangs into required pedestrian access routes. Widen sidewalk to minimum of 7 feet or provide wheel stops.


521.07.090 K
Provide minimum number of required bicycle parking spaces.
Site requires 5 parking spaces.  Proposed location does not appear to meet the standard defined in 21.07.060 F.15 in relationship to primary entrance.

6-
Provide detail for crosswalk striping shown on North east corner of site plan for pedestrian connection to ROW.

7-
Provide Curb Returns per MASS for proposed driveways to existing curb and gutter.  Reference standard mass deteail.

8-
Provide detail for wheel stops for 18 foot parking spaces if sidewalks are not widen to 7 feet around perimeter of building

9IncompleteTraffic comments are incomplete pending submission of additional information.  Additional Comments may be generated.





Advisory Information:

See review number 4
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS