Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To Go Back To Permit Information

Permit Number: C19-1196
Permit Type: Commercial Building Permit - None BldgNew
Address: E 849 DIMOND BLVD Anchorage
Location:
Work Description:

NEW RESTAURANT WITH INDOOR DINING AREA, COMMERCIAL KITCHEN AND DRIVE-THRU LANE - RED

2600 SF - TYPE VB CONST / A-2 OCCUPANCY

Status: Closed
Project Name: RAISING CANE'S
Review Type: Traffic Engineering
Result: Correction
Result Date: 3/12/2019 2:12:10 PM

Comments:

 Code SectionReview CommentStatus



Advisory Information:

comments on 3/7/19 submittal


1. Provide haul route information for import and export of materials.  Identify import and export source locations, Construction hours of operation and point of contact.


2. Provide zoning approved parking calculations for all uses on site.  Number of spaces needed to determine accessible parking needs.  Scope of work appears to modify existing parking for main building. 


3. Review of site plan seems to be relocating or modifying several existing accessible stalls. Detail & on sheet C300 seem to reference only accessible parking for new restaurant.  Please provide additional information for the other relocated or modified spaces.  Please indicate what signs exist and what new signs will be added to main building to meet code requirements for proper signage and striping.  This will applied to the required R7-8/8a accessible signs and R&P-101 for all accessible aisle greater than 5 foot in width.


4. There are 5 18 foot parking spaces in SW Corner that appear to overhang into required landscaping bed and may be impacted by proposed planning materials.  Typical spaces are 9 x 20  and can be 18 feet if there is sufficient area in landscaping aisle.  Please confirm if this landscaping is required and is wide enough to allow parking with zoning,


5. Advisory comments.  Detail 1 on sheet C303 shows detectable warning strips (DWS) being install at all accessible curb ramps.  There is no code requirements to installed these on the private site unless requested by owner.  If these are to remain provide a note call out to this detail for all locations that are applicable on the site plan or remove detail.


Traffic comments are incomplete pending submission of additional information.  Additional comments may be generated. 3-12-19~RR

ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS