Inspection #: 799454
Inspection Type: Shearwall / Exterior
Inspector: P.Calhoun
Result: Correction
Comment: Requesting an inspection to obtain an Approval to Cover (with air barrier) the exterior shear walls (includes holdowns, strapping, and sheathing nail) from grid lines T-Y/10 at all elevations (ground to roof parapet). Requested by: Sloane Tuttle 9079177244 st@akncs.com

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
4/11/2024TransferEXTSNSee Inspector commentsInspector comments Shear wall panels shall be connected to boundary members per shear wall schedule. Straps shall be connected to boundary members. Fasten shear wall panels to bottom plates per shear wall schedule.