Muni.org > Departments > Development Services> Permit Information & Inspection Request
Click Here To View Another Inspection


Inspection #: 675717
Inspection Type: Plumbing Rough
Inspector: K.Hanson
Result: Correction
Comment: Partial Plumbing Rough - Approved DWV/water rough & tests approved, DWV serving units & stacks 104-404, 106-406 & 107-407, water serving units 405, 407, 408, 415 & 416, OK to cover. See corrections.

Inspection Corrections
DateStatusCodeDescriptionRefLocationComments
8/9/2021CorrectedPlumbRgh14CommentsSee Inspectors CommentsWater pipingAs per 2021 UPC 609.10 water hammer arrestors required.
8/9/2021CorrectedPlumbRgh4ABS/PVC SupportABS/PVC horizontal piping shall be supported every 4 feet horizontally- UPC Table 313.1Horizontal underfloor lav DWV 
ADA Compliance      Privacy Statement & Disclaimer      Employee Search      eNewsletter      RSS